What does shade do to a solar array?

It cuts output, and how much depends on what casts the shadow, where it falls and how the panels are wired. The Energy Saving Trust says nearby buildings, trees or chimneys could shade a roof and have a negative impact on the performance of a system. MCS lists shade alongside roof direction and local weather as a factor to research before installing, and tells owners to make sure any shading is minimised where possible.

The wiring matters because a shadow on one panel can affect others. Optimisers and microinverters are the usual answers, covered in one paragraph further down.

How do installers measure shade under MCS?

MCS publishes a Solar PV Shade Evaluation Procedure, reference MGD 005, version 1.0, issued on 16 September 2020. MCS describes it as defining the procedure to assess the potential impact of shading on a solar PV system. It sits alongside MIS 3002, the Solar PV Installation Standard, which MCS updated on 18 March 2026.

The counting steps are in the MGD 005 PDF. MCS's web pages give the title, version and purpose only, so this guide does not reproduce the method, and nothing below is the MCS calculation. What a reader can do is ask to see the shade assessment made for their own roof and ask whether it follows MGD 005.

The idea behind any such assessment is a horizon: obstruction heights, in degrees above flat ground, in each compass direction as seen from the array. PVGIS, the European Commission's solar calculator, works the same way. Its manual says a horizon file lists heights clockwise from north, and that with 36 values PVGIS assumes the first point is due north and the next is 10 degrees east of north, and so on. The horizon PVGIS builds in comes from a terrain model, so a house, tree or chimney has to be added by hand. The next section does that.

How much output can shade cost? A worked example

This is a hypothetical roof, not a survey. The figures come from PVGIS 5.3 (PVGIS-SARAH3 radiation data, 2005 to 2023) for central Birmingham, 1 kWp of crystalline silicon at PVGIS's default 14% system losses, tilted 35 degrees and facing south. An obstruction of fixed height was then added across part of the compass. A 20-degree obstruction is, for example, a neighbouring roofline 4 m above the panels and 11 m away (4 divided by 11 is 0.36, the tangent of 20 degrees).

Obstruction (height, compass range)Annual output per kWp (kWh)Share of unshadedDecember per kWp (kWh)June per kWp (kWh)
None (flat horizon)968.1100%33.15117.05
10 degrees, south-east to south-west (120 to 240 degrees)948.4698%25.57117.05
20 degrees, same arc855.3688%6.73117.05
30 degrees, same arc776.9180%6.73117.05
20 degrees, east to south-south-east (90 to 160 degrees)922.5695%26.83117.05
20 degrees, south-south-west to west (200 to 270 degrees)921.6995%26.33117.05

For a hypothetical 4 kWp array, the unshaded figure is 3,872 kWh a year (4 x 968.1). With the 20-degree obstruction it is 3,421 kWh, which is 451 kWh less. With the 30-degree obstruction it is 3,108 kWh, about 765 kWh less. The two half-arc rows show that the same height costs less when it covers only the morning or only the afternoon: about 5 per cent instead of about 12.

Direction matters as well as height, which is why the angle and direction guide is worth reading alongside this one.

Why does the same obstruction cost more in winter?

Because the sun is lower. The Met Office says the winter solstice has the sun at its lowest midday position, while the summer solstice is when it reaches its highest point in the sky. In the table, the 20-degree obstruction leaves June untouched at 117.05 kWh per kWp but takes December from 33.15 down to 6.73, a loss of about 80 per cent. More than 99 per cent of the 112.7 kWh per kWp lost over the year falls between October and March.

The model has limits. PVGIS handles a distant horizon. A chimney or dormer a few metres from the array shades some panels at some times and not others, which a horizon cannot show. That is a question about how the panels are grouped and wired, and the dormer, hip and small roofs guide shows how awkward roof shapes limit the layout.

What do optimisers and microinverters change?

They change how far one shaded panel spreads its losses. The Energy Saving Trust says optimisers mean that if one panel is shaded, it does not affect how much electricity the other panels can generate, and adds that if the roof has no shading they will not help it generate more. Enphase says that in its microinverter systems the other panels continue to produce fully when one is shaded. SMA says its ShadeFix tracking in some inverters looks for the operating point with the highest output during shading. Which approach suits a roof depends on the shading pattern, and this guide does not compare inverter types. Whether your quote should include optimisers, and what to ask if it does, is covered in solar panel optimisers: when a quote should include them. The pitched roof installation guide shows where string design sits in a full job.

What should you ask an installer about shade before you sign?

  1. Was shade assessed on site or from images, and can you see the assessment made for your roof?
  2. Does it follow the MCS shade procedure (MGD 005), and does the generation estimate show what shade takes off?
  3. Which objects were counted: chimney, dormers, trees, neighbours' roofs? Which panels are affected, and in which months?
  4. How does the design cope: separate inputs, optimisers, microinverters, or leaving shaded positions empty?
  5. Who owns the trees? The Energy Saving Trust says the main upkeep job is keeping nearby trees well trimmed. Work on a tree under a Tree Preservation Order needs the council's consent first, and trees in a conservation area need six weeks' notice before certain work.

Readers who want their roof assessed can send an enquiry through the form on the quote page, and the pitched roof installation guide explains the rest of a pitched-roof job.

Sources

Common questions

Can a reader test their own roof's shading before getting quotes?

Partly. PVGIS accepts a horizon file of obstruction heights measured clockwise from north, and shows the effect on a standard system. It is an approximation, not the MCS assessment an installer produces, so use it to understand the size of the issue and then ask to see the installer's own assessment.

Do optimisers help if the roof has no shade?

The Energy Saving Trust says that if a roof has no shading, optimisers will not help it generate more electricity, though they give extra opportunities to monitor performance. If your roof is unshaded, ask what an optimiser would add to the quote.

Can the tree that shades a roof simply be cut back?

Not always. GOV.UK says anyone wanting to cut down, top, lop or uproot a tree subject to a Tree Preservation Order must first apply to the local planning authority, unless an exception applies. Trees in a conservation area need six weeks' notice for certain work. Check with the council before any pruning.

Does a small amount of shade matter?

It depends on when and where it falls. In the worked example, a 10-degree obstruction across the southern arc cost about 2 per cent of the year, while a 20-degree one cost about 12 per cent. A thin shadow on one panel for an hour matters little if the design isolates that panel.