The best angle and direction for solar panels in the UK, with PVGIS figures
Updated 23 October 2026 · SEO Dons Editorial
What is the best angle and direction for solar panels in the UK?
About 40 degrees of tilt, facing within a few degrees of south. PVGIS, the European Commission's solar model, finds its best fixed position at 39 to 41 degrees in Plymouth, Birmingham and Glasgow, so the best tilt barely changes across the country. The best direction is within five degrees of due south at all three.
| Place | Best tilt | Best direction | kWh per kWp a year |
|---|---|---|---|
| Plymouth | 39 degrees | 2 degrees west of south | 1,123 |
| Birmingham | 40 degrees | 5 degrees east of south | 971 |
| Glasgow | 41 degrees | 2 degrees west of south | 855 |
Settings for every figure on this page: PVGIS 5.3, SARAH3 radiation data for 2005 to 2023, a 1 kWp array of crystalline silicon with 14 per cent system losses, and the terrain horizon switched on. PVGIS gives direction as azimuth, where 0 is south, 90 is west and minus 90 is east, and tilt as the angle from horizontal. Each percentage below is that tilt and direction divided by the best figure for the same place, so the tables show only the shape of the loss.
How much output do you lose at other tilts and directions?
Birmingham first, because its matrix is the full one. A south-facing roof anywhere from 30 to 50 degrees gives 99 or 100 per cent of the best, and 10 degrees gives 90 per cent; a flat array gives 83 per cent. South-east and south-west at 40 degrees give 94 and 93 per cent. East or west at 30 degrees gives 81 and 79 per cent. North falls away fastest as the tilt rises.
| Birmingham: tilt | South | South-east | South-west | East | West | North |
|---|---|---|---|---|---|---|
| 10 degrees | 90 | 88 | 88 | 83 | 82 | 74 |
| 20 degrees | 96 | 92 | 91 | 82 | 81 | 66 |
| 30 degrees | 99 | 94 | 93 | 81 | 79 | 58 |
| 40 degrees | 100 | 94 | 93 | 79 | 77 | 50 |
| 50 degrees | 99 | 93 | 91 | 75 | 73 | 42 |
Plymouth and Glasgow have the same shape. The table compares all three places on the extremes and the most common positions.
| Per cent of best | Plymouth | Birmingham | Glasgow |
|---|---|---|---|
| South, 10 degrees | 91 | 90 | 90 |
| South, 30 degrees | 99 | 99 | 99 |
| South, 40 degrees | 100 | 100 | 100 |
| South, 50 degrees | 99 | 99 | 99 |
| East, 30 degrees | 79 | 81 | 80 |
| West, 30 degrees | 80 | 79 | 81 |
| North, 10 degrees | 75 | 74 | 75 |
| North, 40 degrees | 48 | 50 | 51 |
Tilt matters little for a south roof between 30 and 50 degrees, but direction matters a lot once a roof faces east, west or north.
What does an east-west split give?
The Energy Saving Trust says a system facing east or west tends to get around 15 to 20 per cent less energy than one facing directly south, and PVGIS lands in the same range. For example, take a 4 kWp array in Birmingham, an illustration rather than a design. On a south slope at 30 degrees PVGIS gives about 3,840 kWh a year. Split as 2 kWp east and 2 kWp west at 30 degrees it gives about 3,105 kWh, which is 81 per cent of the south figure. The loss is not even through the year: the split makes 95 per cent of the south array in June and 44 per cent in December.
What a split buys is a flatter day. The table shows the irradiance falling on each array on an average June day, in watts per square metre, with times in UTC; the clocks are an hour ahead in British Summer Time. The east array peaks in the morning, the west in the afternoon, and their average gives more than the south array at 07:00 and 17:00 and less at midday. The east and west average is simple arithmetic on the two PVGIS series.
| Hour (UTC) | South 30 degrees | East 30 degrees | West 30 degrees | East and west average |
|---|---|---|---|---|
| 07:00 | 236.9 | 384.6 | 130.5 | 257.5 |
| 09:00 | 449.0 | 510.6 | 289.1 | 399.9 |
| 12:00 | 582.2 | 494.4 | 498.9 | 496.6 |
| 15:00 | 432.7 | 285.2 | 494.4 | 389.8 |
| 17:00 | 216.7 | 131.4 | 346.9 | 239.2 |
How obstacles on each roof face are judged is a separate question; the shading guide covers it.
Do north-facing panels make sense?
Seldom on a pitched roof. In Birmingham PVGIS gives a north-facing array 74 per cent at 10 degrees, falling to 50 per cent at 40 degrees and 42 per cent at 50 degrees; Plymouth and Glasgow give 48 and 51 per cent at 40 degrees. The Energy Saving Trust says it does not recommend installing panels on a north-facing roof. A vertical south wall, covered in the wall-mounted panels guide, gives 73 per cent in Birmingham, which beats a north roof at 20 degrees or more.
A north slope is worth considering only where it is the one usable surface or the tilt is shallow, because the gap to the best figure narrows from about half at 40 degrees to about a quarter at 10 degrees. Ask for the estimate for that plane on its own, not blended into a single array figure.
How do you use these numbers on a real roof?
- Find your roof's tilt and the compass direction it faces, then read the nearest row and column.
- Remember what PVGIS leaves out. Its horizon estimates shadows from nearby hills or mountains; trees, chimneys and neighbouring buildings need a survey.
- MCS names the factors that decide output as which way the roof faces, shade and the weather, so ask for an estimate that states tilt, direction and shade for each roof face.
- Compare the estimate with the tables. A figure far above them for your tilt and direction needs an explanation.
The generation guide turns kWh per kWp into output for a whole system, the pitched roof installation guide covers roof surveys, and the cost guide covers what moves the price of a system. To have your roof assessed, send an enquiry through the form on the quote page.
Sources
- PVGIS 5.3 PVcalc (query shown: Birmingham, 30 degrees south; other places, tilts and directions change only lat, lon, angle, aspect), European Commission Joint Research Centre (PVGIS-SARAH3, 2005 to 2023), checked 22 October 2026.
- PVGIS 5.3 DRcalc (query shown: Birmingham, June, 30 degrees east), European Commission Joint Research Centre (PVGIS-SARAH3, 2005 to 2023), checked 22 October 2026.
- PVGIS 5 user manual, European Commission Joint Research Centre, checked 22 October 2026.
- PVGIS API non-interactive service, European Commission Joint Research Centre, checked 22 October 2026.
- Solar panels: costs, savings and benefits explained, Energy Saving Trust (Last updated 1 October 2026), checked 22 October 2026.
- Solar panels (consumer guide), MCS, checked 22 October 2026.
- Installing PV arrays on buildings, Historic England (Created 25 March 2024), checked 22 October 2026.
- When do the clocks change?, GOV.UK (Last updated 24 November 2025), checked 22 October 2026.
Common questions
Is a steeper tilt better in winter?
Yes. For Birmingham, PVGIS gives a south-facing array 35.2 kWh per kWp in December at 40 degrees and 41.6 at 70 degrees, but 114.5 in June at 40 degrees against 88.4 at 70 degrees. A steeper tilt moves output towards winter and lowers the yearly total, which peaks near 40 degrees.
How much does a flat or low-pitch roof lose?
In Birmingham, PVGIS gives a south-facing array laid flat 83 per cent of the best figure and 90 per cent at 10 degrees. Historic England says flat-roof panels can be mounted as low as 10 degrees or flat but that this is a compromise and less productive.
Do these figures include shading and weather?
They include the weather as PVGIS models it from satellite data for 2005 to 2023, and the terrain horizon from hills or mountains. They do not model trees, chimneys or neighbouring buildings, so a survey has to add those.
Does the best angle change much between Plymouth and Glasgow?
Not by much. PVGIS puts the best tilt at 39 degrees for Plymouth, 40 for Birmingham and 41 for Glasgow, a spread of two degrees. The yearly output per kWp is lower in Glasgow than in Plymouth, but the angle that gets the most from each place is almost the same.