How much electricity do solar panels generate in the UK? Figures by region and size

Updated 10 November 2026 · SEO Dons Editorial

How much electricity does 1 kWp generate in UK towns?

A kilowatt peak (kWp) is a system's rating under laboratory conditions and the unit used to compare places; the Energy Saving Trust puts the average home system at around 4.5 kWp. The table uses PVGIS, the European Commission's solar calculator, to show what 1 kWp produces at the centre of twelve towns, with a 4 kWp system alongside.

Settings behind every figure on this page: 35 degrees of tilt, facing due south, 14% system losses, PVGIS-SARAH3 radiation data for 2005 to 2023 and the calculated horizon switched on. The sources list gives each run's URL.

TownkWh per kWp a yearAverage kWh per kWp a day4 kWp a year (illustrative: yield x 4)
Plymouth1,121.963.074,488
Southampton1,063.652.914,255
Cardiff1,041.722.854,167
Norwich1,031.302.834,125
Bristol1,022.892.804,092
London1,018.842.794,075
Birmingham968.062.653,872
Liverpool964.992.643,860
Newcastle947.362.603,789
Belfast918.762.523,675
Aberdeen887.402.433,550
Glasgow852.612.343,410

Plymouth is the highest of the twelve at 1,121.96 kWh per kWp and Glasgow the lowest at 852.61, so the same array yields about 24% less in Glasgow (illustrative arithmetic on the two PVGIS figures). London sits at 1,018.84 and Birmingham at 968.06. Belfast stands in for Northern Ireland. The same method applied to more places, ranked against Met Office sunshine records, is in the sunniest places guide. The 4kW solar system guide turns those figures into cost and panel count for a mid-size home system.

How much do 3, 4, 6 and 8 kWp systems generate?

PVGIS was run separately for each size at three places: Plymouth in the south west, Birmingham in the Midlands and Glasgow in central Scotland. Panel counts assume 400 W panels, which is an example rating rather than a recommendation (illustrative arithmetic, rounded up).

System sizePanels at 400 WPlymouth: kWh a yearBirmingham: kWh a yearGlasgow: kWh a year
3 kWp83,366 (9.2 a day)2,904 (8.0 a day)2,558 (7.0 a day)
4 kWp104,488 (12.3 a day)3,872 (10.6 a day)3,410 (9.3 a day)
6 kWp156,732 (18.4 a day)5,808 (15.9 a day)5,116 (14.0 a day)
8 kWp208,976 (24.6 a day)7,744 (21.2 a day)6,821 (18.7 a day)

Output grows in step with size, so the gap between places stays proportional: a 6 kWp array generates 5,116 kWh a year at Glasgow and 6,732 at Plymouth. Size also changes the grid paperwork. Electricity North West says G98 covers installations up to 3.68 kW on a single phase and that anything larger falls into a G99 application, with an inverter's continuous steady state rating taken as the installation's rating. The G98 and G99 guide therefore matters most for the 6 and 8 kWp rows, and the cost guide covers what moves the price of each size.

How does output change month by month?

PVGIS also reports monthly averages. The table gives the output of a 4 kWp system, with the average day in brackets, in kilowatt hours.

MonthPlymouthBirminghamGlasgow
January165 (5.3 a day)149 (4.8 a day)95 (3.1 a day)
February238 (8.5 a day)206 (7.4 a day)162 (5.8 a day)
March382 (12.3 a day)336 (10.8 a day)289 (9.3 a day)
April518 (17.3 a day)433 (14.4 a day)411 (13.7 a day)
May553 (17.8 a day)469 (15.1 a day)463 (14.9 a day)
June552 (18.4 a day)468 (15.6 a day)440 (14.7 a day)
July542 (17.5 a day)472 (15.2 a day)444 (14.3 a day)
August502 (16.2 a day)425 (13.7 a day)387 (12.5 a day)
September414 (13.8 a day)361 (12.0 a day)300 (10.0 a day)
October283 (9.1 a day)251 (8.1 a day)209 (6.8 a day)
November195 (6.5 a day)169 (5.7 a day)133 (4.4 a day)
December144 (4.7 a day)133 (4.3 a day)77 (2.5 a day)

The best month produces 3.8 times the worst at Plymouth, 3.6 times at Birmingham and 6.0 times at Glasgow (illustrative arithmetic on the table). Averages also hide the weather. PVGIS reports the year-to-year standard deviation of monthly output, and for 1 kWp at Birmingham it is 13.42 kWh in July against an average of 118.06 kWh, about 11%. Over a year the spread narrows to 34.25 kWh per kWp, about 3.5%. Set against a car's needs, these monthly figures explain why charging an electric car with solar panels works far better in summer than in winter.

Why does a 400 W panel rarely produce 400 W?

The rating is a laboratory figure. PVGIS defines nominal or peak power as the power claimed by the manufacturer, measured at 1,000 watts of sunlight per square metre and a module temperature of 25 degrees C, conditions called Standard Test Conditions. A UK roof averages far below them: PVGIS gives 3.27 kWh per square metre a day on a 35 degree slope at Birmingham, which is 136 watts per square metre averaged over 24 hours (illustrative arithmetic), and the panel then loses energy on the way to the socket.

PVGIS itemises some of those losses. For 1 kWp at Birmingham it reports an angle of incidence loss of 3.21%, a temperature and irradiance loss of 4.26% and a total loss of 18.87% with its 14% system-loss default included. The manual attributes system losses to causes such as cables, inverters and dirt on the modules.

Averaged over all 8,760 hours of a year, 1 kWp at Birmingham delivers 968.06 kWh divided by 8,760, or about 0.11 kW. A 400 W panel therefore averages roughly 44 W (illustrative arithmetic). The average includes the night, so it is not what a panel does at noon, but it explains why annual totals look small against ratings.

Is 6 kW or 10 kW of solar enough to run a house?

Across a year, comfortably; the catch is timing. A kW figure is the size of a system and a kWh figure is energy over time. The Department for Energy Security and Net Zero reports median domestic electricity use in England and Wales in 2024 of 2,500 kWh, with an upper quartile of 4,100 kWh. Its figures count electricity drawn from the grid and ignore on-site generation. Ofgem's own typical consumption values for comparing bills are being updated from 1 July 2026; this page uses the department's table, which is published on an accessible page.

SystemBirmingham output a year (kWh)Multiple of median useMultiple of upper quartile use
3 kWp2,9041.20.7
4 kWp3,8721.50.9
6 kWp5,8082.31.4
8 kWp7,7443.11.9
10 kWp9,6813.92.4

The multiples are illustrative arithmetic on PVGIS and the department's figures. At the Birmingham coordinates a 6 kWp system averages 6.4 kWh a day in December and 23.4 kWh in June (PVGIS), against 6.8 kWh a day for the median home averaged over the year (2,500 divided by 365). Electricity arrives in daylight, so evening demand comes from the grid unless a battery stores the surplus; the guide to solar without a battery covers that trade-off.

What do these figures leave out?

They describe a plain south-facing slope at 35 degrees at the centre of each town. PVGIS includes a calculated horizon that estimates shadows from hills and mountains; shade from a neighbour's tree or chimney, a different pitch or an east-west split will all change a real roof's result. The guide to how many panels you need shows how orientation moves the panel count. A reader who wants to compare quotes can send an enquiry through the site's quote form, but a roof survey, not a table, settles what a particular roof produces.

Sources

Common questions

How many kWh does one 400 W panel produce in a year?

About 387 kWh at the Birmingham coordinates, 341 kWh at Glasgow and 449 kWh at Plymouth. That is the PVGIS figure for 1 kWp multiplied by 0.4 (illustrative, south-facing at 35 degrees).

Do the PVGIS figures allow for cloud?

Yes. PVGIS says its radiation data come from satellite images used to identify the presence and thickness of clouds, so its averages allow for cloud. A single day can still fall far from the average.

Will my own system match these figures?

Not exactly. The yearly standard deviation for 1 kWp at Birmingham is 34.25 kWh, and roof direction, pitch and shade move the result further. Use the tables to compare places and sizes.

What is the difference between kW and kWp?

The kWp is the panel rating under standard test conditions, which the Energy Saving Trust calls the maximum a system can generate in ideal conditions. The kW of an inverter is its output limit, and kWh measures energy over time.