How many solar panels do you need? Sizing from your electricity use

Updated 10 November 2026 · SEO Dons Editorial

How do you size a system from your electricity use?

Work from the electricity you buy now, not from the roof. There are four steps.

  1. Take your annual use in kWh from twelve months of bills or a smart meter, or start from the typical figures below.
  2. Add any big new loads, such as an electric car or heat pump.
  3. Divide the total by the yearly output of one kilowatt of panels where you live, taken from PVGIS.
  4. Divide the resulting kWp by the wattage of one panel and round up.

Current panels are listed at roughly 415 to 485 W: JA Solar and Qcells give top outputs of 440 to 455 W for their residential modules, Octopus Energy says it fits 455 W panels and E.ON Next fits 485 W. This guide uses 440 W, a power JA Solar lists for its JAM54S31 LR.

A worked example shows the arithmetic. A home using 2,500 kWh at Birmingham, where PVGIS gives 968 kWh per kWp, needs 2,500 ÷ 968 = 2.58 kWp. Dividing by 0.44 kW per panel gives 5.9, so six panels. The answer is the number of panels whose output over a year matches your use. It is a starting point, and the later sections cover the limits set by season, roof and grid connection. For prices, see the cost of solar panels for a 3 bedroom house and other home sizes.

What counts as typical electricity use?

DESNZ's National Energy Efficiency Data-Framework (NEED), published on 11 June 2026, reports 2024 consumption as a lower quartile, median and upper quartile. In England and Wales these were 1,600, 2,500 and 4,100 kWh; in Scotland they were 1,500, 2,400 and 3,900 kWh. The figures are gross grid consumption and ignore any electricity generated on site, so a home that already has solar looks lower than its true use. Ofgem sets its own typical values for the price cap and said it would implement updated ones from 1 July 2026; the quartiles here come from NEED.

Your own figure beats any average. NEED finds that median consumption is higher for larger properties and rises with the number of adults, and that detached houses use the most. DESNZ's regional statistics add a geographic pattern: the North East's mean domestic use is about 15 per cent below the Great Britain average, while in 2024 the South East was 10 per cent above it, the East 9 per cent and the South West 6 per cent. The Great Britain mean was 3,323 kWh.

How many panels does each region need?

PVGIS, the European Commission's solar tool, gives the yearly output of 1 kWp for a place, slope and orientation. The table uses PVGIS-SARAH3 data for a south-facing 35 degree slope with PVGIS's standard 14% losses, at city-centre coordinates, with 440 W panels and counts rounded up. Scottish rows use the Scottish quartiles.

PlacePVGIS kWh per kWp a yearPanels at lower quartile usePanels at median usePanels at upper quartile use
Plymouth1,122469
London1,0194610
Norwich1,0314610
Birmingham9684610
Manchester8865711
Leeds9474610
Newcastle9474610
Cardiff1,042469
Glasgow8534711
Aberdeen8874710

Region moves the answer by one to two panels; the household's own use moves it far more, since the upper quartile needs more than twice the panels of the lower quartile. Orientation matters about as much as region. A roof split east and west at Birmingham averages about 766 kWh per kWp, 21 per cent below south, so the median home would need 8 panels instead of 6.

Will that many panels fit?

JA Solar's page gives 1,762 × 1,134 mm for its 440 W panel, about 2.0 m². Six panels therefore need about 12 m² of panel area and ten about 20 m², before any edge gap. The solar panel sizes guide shows why the usable rectangle matters more than total roof area: an illustrative 6.0 m by 4.8 m slope fits eight panels with a 0.4 m gap, not the fourteen that dividing areas suggests. To check how many panels your own roof can take, the solar panel roof calculator counts whole rows on each face from your measurements.

How much do an electric car or heat pump add?

Add the extra kWh from each. For a car, divide annual miles by the car's miles per kWh. For a heat pump, take the annual electricity use predicted in its design. The figures below are assumptions for the arithmetic, not statistics: a car driven 6,000 miles at 3.5 miles per kWh adds about 1,714 kWh, and a heat pump predicted to use 3,000 kWh adds that. At Birmingham yields, the median home at 2,500 kWh needs 6 panels; with the car, 4,214 kWh needs 10; with the car and the heat pump, 7,214 kWh needs 17, which is about 34 m² of panel at 2.0 m² each. Many roofs cannot take that, and then the array is trimmed to the roof and covers part of the use. How much of a car's charging the panels can actually supply, month by month, is worked through in charging an electric car with solar panels.

Does matching annual use cover the house?

No, because annual totals hide the seasons and the clock. PVGIS gives 40.7 kWh per kWp in January and 123.2 kWh in July for a south slope at London, three times as much in July, and nothing is generated at night. A system sized to a year's use therefore generates more than a home needs in summer and less in winter, and the grid supplies the gap. The guide to how much electricity solar panels generate goes through output by month.

Does the number of panels change the grid paperwork?

It can. Electricity North West says G98 applies to generation installations up to 16 amps per phase, meaning single-phase systems up to 3.68 kW, and that anything larger falls into a G99 application. Where an installation includes an inverter, it treats the installation as the size of the inverter's continuous steady state output. So ten 440 W panels, 4.4 kWp, can still be a G98 installation if the inverter is rated 3.68 kW or less (derived). SSEN says a G98 installer submits Form B within 28 days of commissioning, and that you must apply before you connect if the total generation at a site exceeds the G98 limits. Inverter sizing is covered in what size inverter you need.

Once you have a panel count, the cost guide explains how DESNZ's per-kilowatt data applies to a quote. To gather quotes for your array, you can send an enquiry through this site's quote form.

Sources

Common questions

How many solar panels do I need for a 4-bedroom house?

Bedrooms do not set the number; electricity use does. NEED finds median use is higher for larger properties and rises with adults in the household. A home at the upper quartile of 4,100 kWh needs about ten 440 W panels in central England to match its use over a year.

Is 6 kWp of panels enough to run a house?

At Birmingham yields, 6 kWp would generate about 5,800 kWh a year, more than twice the median home's 2,500 kWh. It only generates in daylight, though, and London's January output is about a third of July's. Six kilowatts of inverter output would also exceed the 3.68 kW G98 limit, so it would need G99 approval first.

Does a roof facing east or west need more panels?

Yes. PVGIS gives about 775 kWh per kWp for an east-facing and about 757 for a west-facing 35 degree slope at Birmingham coordinates, against 968 for south. For the median 2,500 kWh, an east-west split needs about 8 panels of 440 W rather than 6.

Do the NEED figures include homes that already have solar?

They count electricity drawn from the grid and ignore any generated on site, so homes with panels appear to use less than they do. If you already have solar, add your own generation to your grid imports before using these figures.