solarpanelsandinstallation

Solar panel sizes in the UK: dimensions, weight and how many fit on a roof

Updated 10 November 2026 · SEO Dons Editorial

What size are current home solar panels?

Manufacturers publish sizes, weights and power on their product pages. The table gathers residential modules from those pages, read on 22 October 2026. Where a page gives a power range, the area per kilowatt is derived by dividing the panel's length times width by the top of that range. The guides to a 4kW solar system and a 10kW solar system show how many panels each needs.

ModuleRated powerEfficiencyLength × width (mm)Weight (kg)Panel area per kW (m²)
JA Solar JAM54S41 LR, all black430-455 W22.8%1,762 × 1,134204.39
JA Solar JAM54S31 LR, all black415-440 W22%1,762 × 1,134204.54
JA Solar JAM54D40 GB 25Y420-445 W22.8%1,722 × 1,13421.54.39
JA Solar JAM54D40 LB 25Y430-455 W22.8%1,762 × 1,134224.39
Qcells Q.TRON BLK M-G2+415-440 Wpup to 22.5%1,722 × 1,13321.24.43
Qcells Q.PEAK DUO BLK ML-G10+395-415 Wpup to 21.1%1,880 × 1,04422.04.73
JA Solar JAM60D42 LB, longer format515-540 W23.1%2,063 × 1,13428.84.33

Qcells' product pages give sizes in inches and pounds (67.8 × 44.6 × 1.18 in and 46.7 lb for the Q.TRON; 74 × 41.1 × 1.26 in and 48.5 lb for the Q.PEAK DUO), converted above. REC's product page gives areas instead of dimensions: 1.93 m² for the 400-430 Wp Alpha Pure-R and 2.08 m² for the 450-470 Wp Alpha Pure-RX. Suppliers name panels in the same class: Octopus Energy says its packages use 455 W JA Solar panels, each 1.7 m by 1.1 m, and E.ON Next's packages use 485 W Aiko panels.

What do the datasheets have in common?

  • Footprint holds, watts rise. The JAM54S31 LR and JAM54S41 LR share a 1,762 × 1,134 mm footprint and a 20 kg weight, but the top output moves from 440 W to 455 W. Qcells' ML-G10+ tops out at 415 Wp in about 1.96 m², while its latest Q.TRON reaches 440 Wp in about 1.95 m². The same roof can carry more kilowatts from the same number of panels.
  • Residential panels cluster. Lengths run from 1.72 to 1.88 m, widths from 1.04 to 1.13 m, and weights from 20 to 22 kg. Efficiency runs from 21.1% to 23.1%, and higher efficiency means more watts from the same area.
  • Longer formats exist. JA Solar's 2,063 mm module weighs 28.8 kg. Lengths differ by more than 30 cm between formats, so a roof drawing has to use the exact module's datasheet.
  • A range is several power classes. Each page gives a range, such as 430-455 W for the JAM54S41 LR, so a quote should name the exact class: 25 W on a 440 W panel is about 6%.
  • Orientation is a design choice. JA Solar's pages list cable lengths of 300 mm and 400 mm for portrait mounting and 1,200 mm each for landscape, so the layout also affects the cabling.

How much does a solar panel weigh on the roof?

The panels in the table weigh 20 to 22 kg, which is about 10 to 11 kg per square metre of panel (derived), or about 12 kg for the longer format. That excludes rails, clamps and hooks. The checks on rafters and roof covering that sit behind the number are described in the installation guide.

How much roof does each kilowatt need?

From the table, panel area comes to 4.3 to 4.7 m² per kilowatt, and about 4.4 m² for the top-rated 54-cell modules. On 440 W panels of about 2.0 m² each, six panels (2.64 kW) cover about 12 m², eight (3.52 kW) about 16 m², ten (4.40 kW) about 20 m² and fourteen (6.16 kW) about 28 m². Those are panel areas only, and edge gaps and obstructions take more roof, as the next section shows. To work out how many panels your electricity use points to, see the guide to sizing a system from your consumption.

How many panels fit on a terrace, semi or detached roof?

These are illustrations, not surveys. They use a 440 W panel of 1,762 × 1,134 mm (the JAM54S31 LR page) and a 0.4 m gap round the array, the roof edge allowance that Octopus Energy's FAQ adds to its panel size. The real gap on a roof comes from the designer, so ask which figure the drawing uses. Output is PVGIS's estimate for Birmingham coordinates on a 35 degree slope with its standard 14% losses.

IllustrationRoof plane (m)Usable after gap (m)Panels, portrait / landscapeArray (kWp)PVGIS yield (kWh a year)Roof area ÷ panel area
Terrace rear slope, west-facing4.8 × 3.64.0 × 2.83 / 41.76about 1,3308
Semi rear slope, south-facing6.0 × 4.85.2 × 4.08 / 63.52about 3,41014
Detached main slope, south-facing9.5 × 4.88.7 × 4.014 / 126.16about 5,96022

Dividing roof area by panel area gives 8, 14 and 22 panels, which is 1.6 to 2 times what the layouts fit, because panels cover only 46% to 61% of each plane once the gap and whole-panel steps are applied. The count moves in whole panels, so a few centimetres can add or remove a row. The west-facing terrace slope yields about 757 kWh per kWp, against 968 for the south-facing ones.

How do you check the fit on your own roof?

  1. Measure each roof plane along the slope, not the floor plan: the width along the ridge and the length from eaves to ridge.
  2. Deduct the gap from every side, and mark off chimneys, roof windows, vents and hips. The guide to dormers, hips and small roofs covers those.
  3. Divide the usable width and height by the panel's width and length for portrait, then by length and width for landscape, rounding each result down.
  4. Multiply columns by rows for each orientation, keep the higher count, and multiply by the panel's rated power for the array's kWp. The solar panel roof calculator runs this row-by-row method for any face, panel size and edge allowance.

Array size is what a quote is judged on, so the cost guide is the next stop once you know your fit. To get quotes to compare, you can send an enquiry through this site's quote form.

Sources

Common questions

What is the standard size of a solar panel in the UK?

There is no single standard. The residential panels in the table are mostly 1,722 to 1,762 mm long and 1,134 mm wide, and Octopus describes its panels as 1.7 m by 1.1 m. Other designs differ: Qcells' ML-G10+ is about 1,880 by 1,044 mm.

Does a 440 W panel produce 440 W?

Not continuously. PVGIS estimates 968 kWh a year per kilowatt of panels on a south-facing 35 degree roof at Birmingham coordinates, which averages about 110 W per kilowatt across all hours. For one 440 W panel that is about 49 W on average, or roughly 426 kWh a year (derived).

Do higher-wattage panels mean fewer panels?

For the same capacity, yes. Ten 440 W panels give 4.4 kWp, while nine 485 W panels, the output E.ON Next lists for its Aiko panels, give about 4.37 kWp. How much roof that saves depends on the larger panel's dimensions, so check its datasheet.

What roof size does a 4 kW array need?

About ten 440 W panels, or 4.4 kWp. Two portrait rows of five take 5.67 m by 3.52 m of roof, so with a 0.4 m gap round the array the slope needs to be at least about 6.5 m by 4.3 m (derived), before any chimney or roof window.

Get an installation quote

By submitting you agree to our privacy policy. We never sell your details.

Get a quote
Get a quote