Solar panel mounting systems: rails, roof hooks and flashings explained
Updated 10 November 2026 · SEO Dons Editorial
What are the parts of a solar panel mounting system?
On a pitched roof, most installations use four parts: roof hooks fixed to the rafters, rails bolted to the hooks, clamps that hold the panel frames to the rails, and flashings or boards that keep the covering watertight where a hook passes through it. Historic England describes the same chain: the array is clamped to a pair of rails, and the rails are fixed to the rafters by roof anchors.
| Part | What it does | What the sources say |
|---|---|---|
| Roof hook (roof anchor) | Fixes to a rafter through the roof covering and carries the rail | Historic England: rails are fixed to the rafters by roof anchors; K2's SingleHook 3S Light is described for rafters from 48 mm |
| Rail | Spans the hooks and carries the panels | K2 lists its rails in aluminium EN AW-6063 T66 with static confirmation in K2 Base |
| Clamp | Grips the panel frame to the rail | Historic England: the array is clamped to a pair of rails |
| Flashing or board | Keeps water out where a hook passes the covering | Historic England: a proprietary clamp or lead flashing on slate; tiles lifted and notched |
MCS says certified installers use MCS certified products, including mounting kits. Installers should be able to name the kit's make and model, and the in-roof against on-roof guide explains how the MCS 012 standard treats the two designs. The installation guide covers the day itself.
Which roof hook suits which roof covering?
The hook has to reach the rafter without damaging the covering, so its shape follows the covering. Historic England says the type of roof anchor depends on the existing covering and on the height and spacing of the battens. The table gives one manufacturer's catalogue as an example; it is not a recommendation, and other makers' ranges differ.
| Covering | Hook approach | One maker's example |
|---|---|---|
| Concrete interlocking tile | Narrow bracket that passes between tiles, fixed to the rafter; tiles lifted and the one above notched | K2 SingleHook 3S Light has a 6 mm bracket for fitting between tiles; SingleHook 2 suits flat concrete tiles to BS EN 490 |
| Plain clay tile | A hook made for plain tiles, taken to the rafter with the tile above notched | K2 says hook solutions exist for plain tiles and flat concrete tiles as special roof shapes |
| Slate | A long flat bracket plus a clamp, lead flashing or replacement-slate flashing; never a hole through a slate | K2 slate hook: 40 x 250 x 6 mm stainless steel bracket; Valk: hook on the wood under the slates with a flashing that replaces one slate |
For tiles, Historic England says anchors are typically fixed to the rafters by lifting the tiles and notching the underside of the tile above the anchor, so that no gaps open in the covering. For slate, it says installers should never drill through slates because that risks cracking them and lets water in. The slate roof guide goes further into slate. What each type of tile means for the hook, broken tiles and spares is covered tile by tile in solar panels on a tiled roof.
What do wind and snow loading mean for hook spacing?
Wind can lift an array as well as push on it, and snow adds weight. Historic England says the roof has to carry the additional wind, snow and static load, which a qualified structural engineer must check, and that a typical panel weighs 15kg/m2. It adds that uplift varies with the layout and orientation of the panels and the location of the building.
Hook spacing and rail span are therefore outputs of a calculation, not a standard figure. K2's planning tool, for one, determines wind and snow loads automatically and then calculates the roof fasteners. When MCS updated MIS 3002 on 18 March 2026, clause 5.5.5 was extended to cover installations where no certified mounting system exists under MCS 012. The installer must be able to evidence completed structural and wind loading calculations for the specific mounting system, and the update became mandatory for MCS installers from 18 June 2026.
The calculation also matters to the mounting warranty. K2's terms give twelve years from commissioning, extended to 20 years where the system is planned in K2 Base and documented, and exclude failures that follow from ignoring the static calculation or the assembly instructions. Other makers' terms differ, so read the one for your kit.
How do flashings keep water out around the hooks?
Every hook is a potential route for water. The NFRC says fixings penetrate the roof covering, panels add weight, and the array changes how water drains across the roof. On tiles the answer is to lift and notch so the tiles still lie as designed. On slate, Historic England asks for a proprietary clamp or lead flashing, and Van der Valk shows the replacement-slate version: its hook mounts on the wood under the slates, with a flashing that replaces one slate. MCS now asks installers using a kit without MCS 012 certification to show how weather-tightness has been maintained. In-roof systems handle this differently; see in-roof kits compared.
Does portrait or landscape change the fixings?
It changes where rails cross rafters and how load spreads, which is why the layout belongs in the loading calculation. Historic England says uplift depends on the layout and orientation of the panels, and that a symmetrical layout, all portrait or all landscape, looks better. Some hooks come in matching versions: Van der Valk's slate hook is sold in vertical and horizontal forms for portrait and landscape. Rafter spacing governs hook positions, and K2 offers boards for awkward spacing. Historic England also asks for a clear area for access and maintenance. Flat roofs use different frames; see flat roof solar mounting.
What should an installer be able to show you?
- The make and model of the mounting kit, and whether it is MCS 012 certified.
- For a kit without certification, the four items MCS now lists: structural and wind loading calculations, fire performance after installation, weather-tightness after installation, and that the components are compatible.
- Written confirmation that the installation follows the manufacturer's instructions.
- The hook type chosen for your covering and how the rafters were located.
- A plan for broken tiles or slates; Historic England says some may break and that replacements should be to hand.
The pitched roof installation guide shows where mounting fits in a full installation. To have your roof assessed, send an enquiry through the form on the quote page. What the whole job costs at each system size is set out in the solar panel installation cost guide.
Sources
- Installing PV arrays on buildings, Historic England (Created 25 March 2024), checked 22 October 2026.
- Considerations when planning a PV installation, Historic England (Created 25 March 2024), checked 22 October 2026.
- MCS publishes update to MIS 3002, MCS (18 March 2026), checked 22 October 2026.
- Solar panels (consumer guide), MCS, checked 22 October 2026.
- Roof fasteners, K2 Systems (own products), checked 22 October 2026.
- Roof tiles, K2 Systems (own products), checked 22 October 2026.
- SingleRail System, K2 Systems (own products), checked 22 October 2026.
- K2 Base, K2 Systems (own product), checked 22 October 2026.
- Warranty terms and conditions, K2 Systems (own terms), checked 22 October 2026.
- Slate hook catalogue entry, K2 Systems (own product), checked 22 October 2026.
- Solar panels on slate roofs, Van der Valk Solar Systems (own products), checked 22 October 2026.
- ValkPitched slate roof hook and Genius Speedflash upgrade, Van der Valk Solar Systems (own products), checked 22 October 2026.
- When solar PV is installed on end-of-life roofs, NFRC (26 March 2026), checked 22 October 2026.
Common questions
Are stainless steel hooks better than aluminium ones?
The sources checked do not rank materials. K2 lists some hooks in aluminium with stainless steel fixings and others, including its slate hook, in stainless steel. Ask for the maker's data sheet and the load calculation for the hook actually specified rather than choosing by metal.
Can a roof hook be fitted without lifting any tiles?
Not usually on a tiled roof. Historic England says anchors are typically fixed to the rafters by lifting the existing tiles and notching the tile above. On slate, Van der Valk says its hook mounts on the wood under the slates.
How much weight does an array add to a roof?
Historic England gives a typical panel weight of 15kg/m2 and calls it a small increase in the static load of the roof. It also lists cases needing strengthening, such as decayed timbers or a roof already heavily loaded by a very heavy covering, so a structural check is still needed.
Does MCS require certified mounting kits?
MCS says certified installers use MCS certified products, including mounting kits. For installations with no certified mounting system under MCS 012, clause 5.5.5 of MIS 3002 sets out what the installer must evidence, and the update became mandatory from 18 June 2026.