How do the main in-roof kits differ?

The table uses each maker's own web pages, checked on 22 October 2026. Pitch ranges and some fire classes sit in datasheets that are not on those pages, so "not on the page" means exactly that, not "not available". The table shows what each maker publishes; it is not a specification and it ranks nothing.

KitPanel formats and sizes on the pageRoof coverings namedFire class statedPitch and fit information
GSE IN-ROOF SYSTEMPortrait or landscape. Frames come in two parts so larger and wider modules fit, and a frame reference number is matched to the panel.Says the panels replace part of the tiles. No list of coverings on the page.None on the page. It describes the system as having excellent fire and impact resistance.No pitch range on the page. Compatible with VELUX, FAKRO and ROTO roof windows.
Viridian Clearline fusionPV16 modules at 335 W and 340 W (G1) and 405 W and 445 W (M10), portrait or landscape.Universal kit for all common tiles and slates, with special fixing kits for Scottish-practice slate.Says Fusion achieves the highest fire rating. Its literature page lists BRoof T1, T2, T3 and T4.Technical note T013 covers pitches below 20 degrees. Standard brackets suit battens of 25 mm and above, with separate brackets for 22 mm and 40 mm.
Marley SolarTile335 Wp panel 1000 mm wide by 1686 mm high; 445 Wp panel 1134 mm by 1722 mm. Portrait or landscape.Marley roof coverings including clay and concrete tiles and cedar shingles and shakes. Says it replaces standard tiles or slates.Broof (T1, T2, T3, T4) under EN 13501-5.Says suitable for low-pitch roofs, with a separate pitch datasheet. Roof loading 12.9 kg/m2 (335 Wp) and 14.5 kg/m2 (445 Wp). System warranty 15 years.

How does each kit keep the weather out?

All three work by making the panel part of the roof covering, with flashings around it. They differ in how the parts are supplied.

  • Marley says the panels and flashing kits are fixed directly to the battens in a new build or full re-roof, with the surrounding covering built around them. For a retrofit it describes removing a section of tiles, fitting the panels and re-tiling up to the flashings. Its flashing kits are colour-coded.
  • Viridian says six flashing kits combine into rectangular arrays in portrait or landscape, and five further kits form inside corners for stepped arrays. Its kits are designed for its own Clearline PV16 modules.
  • GSE says its panels are built into the roof and replace part of the tiles, using a frame system matched to the panel.

The in-roof versus on-roof guide explains the MCS 012 weathertightness tests that apply to any certified kit, so they are not repeated here.

What does an installer need to know about your roof?

  • Pitch. Viridian's note on low-pitch installation covers pitches below 20 degrees and says the detail may also suit roofs close to the minimum pitch (below 25 degrees) with extra risk factors. Ask each maker's pitch range for the exact kit and panel.
  • Covering and battens. Batten thickness changes which brackets are supplied, and Viridian says slate laid in the Scottish style on sarking boards needs special fixings.
  • Exposure. Viridian says wind pressures are higher when solar is roof integrated, and that some products are not strong enough for exposed locations or near the edge zones of a roof. Ask for the certified wind figure and the location it was assumed for.
  • Roof windows. GSE and Viridian both publish roof-window arrangements. Say if a window sits within or beside the array.
  • Ventilation. Viridian says NHBC's 2024 guidance treats any roof pitch with roof-integrated solar as having an impermeable covering. NFRC publishes guidance note GN64 on ventilating pitched roofs where integrated panels are fitted in tiled and slated roofs with LR and HR underlays. Ask who checked ventilation on your roof.
  • Panel match. Viridian says its flashing kits work with its Clearline PV16 modules, and GSE matches frames to your panel size. Ask which panels the kit is certified with.

Do in-roof kits lose output?

Viridian says research with Cambridge University found that the reduction in energy yield from roof-integrated panels was very small, of order only 3%. That is a maker's statement about its own system. Ask the installer what ventilation or temperature allowance sits behind the yield estimate for each kit quoted, and whether the same allowance was used for every option.

How should you read the makers' claims?

Viridian says its certified wind resistance is more than double that of competitor products. Marley says its certified wind resistance is more than four times higher than competitor PV roof tiles. The two statements compare against different products. Marley's specification table gives characteristic wind resistance of 5.32 kPa for its 335 Wp panel and 4.65 kPa for its 445 Wp panel, while Viridian says both its panel types exceeded the maximum force the test laboratory equipment can apply. Compare the certified numbers for your roof build-up instead. Viridian's note T007 says its system has been tested with a wide range of roof build-ups, which is the question to ask of any kit.

Check current MCS status too. MCS says the Product Directory can be searched by technology type, certification status and certification period. Ask the installer for the datasheet revision date and the fire certificate for the exact kit and panel proposed. This guide gives no prices and does not recommend a kit; for installed prices by system size, see the solar panel installation cost guide, where in-roof trays are one of the lines that move a quote.

What about other in-roof kits?

Other makers sell in-roof kits as well, and the same five requests apply to any of them: the panel sizes the kit takes, the coverings it is approved for, the fire classification certificate, the pitch range, and the datasheet revision date. A kit whose maker or installer cannot supply those is hard to compare fairly.

Where to go next

If the covering is being replaced anyway, the in-roof installation guide explains the method and when it makes sense. For panels that already sit on a roof needing repair, see removing and refitting solar panels for roof work. Slate roofs raise their own fixing questions, covered in solar panels on a slate roof, and the in-roof versus on-roof guide sets the two approaches side by side. Readers who want a kit specified for their own roof can send an enquiry through the site's enquiry form.

Sources

Common questions

Can any panel be used with an in-roof kit?

Not usually. Viridian says its flashing kits work with its Clearline PV16 modules, and GSE says a frame reference number is matched to your panel. Ask which panels the proposed kit is certified with before agreeing a substitute.

Do in-roof kits suit slate as well as tile?

It depends on the kit. Viridian says its universal kit works with all common tiles and slates, with special fixings for Scottish-practice slate. Marley names its own coverings and says SolarTile replaces standard tiles or slates, and the GSE page lists no coverings, so ask each maker for written confirmation.

What fire class should an in-roof kit state?

Marley states Broof (T1, T2, T3, T4) and Viridian lists BRoof T1 to T4 classification reports, while the GSE page checked gives no class. Ask for the classification certificate for the exact kit and panel proposed for your roof.

Can an in-roof array sit next to a roof window?

Several makers publish arrangements for it. GSE says its system is compatible with VELUX, FAKRO and ROTO roof windows, and Viridian lists a flashing kit for VELUX windows. Tell the installer where any window sits before the layout is drawn.