Ground-mounted solar at home: frames, footings and running the cable to the house

Updated 23 October 2026 · SEO Dons Editorial

What holds a ground-mounted array down?

Makers offer several footing types for one frame, and the choice is a site decision. One maker's catalogue, used here as an example and not a recommendation, sells connection kits for four: concrete foundations, screw foundations, pile foundations and gabions.

FootingWhat the makers' pages say
ConcreteK2 Systems sells a "kit for connecting the N-Rack to concrete foundations". For one small kit it adds that the foundations "must be procured on site or constructed by the customer"
ScrewA "set for connecting the N-Rack to screw foundations", with a 1.3 metre screw foundation listed separately and "procured on an order-by-order basis"
Driven pileA "kit for connecting the N-Rack to pile foundations"
GabionA "set for attaching the N-Rack to gabions", with steel-wire mesh baskets listed in two sizes
Ballast blocksVan der Valk Solar Systems says "no anchoring points have to be drilled into the ground" and that concrete blocks "provide the necessary ballast"

A kit also has design limits. A small ground kit in the same catalogue is "designed for a snow load of up to 1.75 kN/m² and a wind load of up to 0.67 kN/m²". The loads at your site have to be worked out and set against what the frame quoted is designed for. MCS updated clause 5.5.5 of its installation standard, MIS 3002, for installations where no certified mounting system is available under MCS 012, and the update became mandatory for MCS installers on 18 June 2026. The installer must be able to evidence "completed structural and wind loading calculations in relation to the specific mounting system being installed". Ask whether the frame is MCS 012 certified and, if not, ask to see those calculations. The mounting systems guide covers the roof equivalents.

How do the planning limits shape the frame?

In England a house's stand-alone array is capped at 4, 2 or 1 metre high depending on position, with 9 square metres of panels; the planning rules guide sets out the table. Those caps fix the tilt and height of the frame before anything else. At 9 square metres the array is only a handful of panels, so row spacing seldom decides the layout in a house garden. Where a larger array has planning permission, the designer has to leave gaps between rows so the front row does not shade the next when the sun is low. Ask for the spacing drawing, and see the shading guide for how shade is assessed.

How far can the array be from the house?

Class B sets no maximum distance from the house. Its test is that the array stands "within the curtilage of a dwellinghouse", and the boundary rules in the planning guide still apply. The limit that bites is electrical: voltage drop.

BS 7671 gives recommended maximum voltage drops in Table 4Ab of its Appendix 4. The IET calls them "informative because the actual values of voltage drop depend on the requirements of the connected equipment". Its worked example sets a voltage-drop allowance and then derives maximum circuit lengths, so distance and cable size are linked. The remedy it names is that "the designer may choose to select a larger CSA conductor", with the caution to "take account of the maximum conductor size for the terminals in the equipment". A quote should rest on the measured route length and the calculated drop, not a guess.

Should the long run carry AC or DC, and what cable does each need?

That depends on where the inverter stands. The IET says UK solar inverters are "predominantly transformerless, using an unearthed DC system".

Inverter positionWhat crosses the gardenWhat the IET says
At the houseDC string cableInsulated and sheathed cable without metallic armour, such as to BS EN 50618; buried DC cable in a duct meeting N750; single-insulated armoured cable "is not permitted"
At the arrayAC cableA buried cable needs an "earthed armour or metallic sheath or both", or a duct giving equivalent protection; armoured cable "is used in AC systems where there is an increased risk of mechanical damage"

The DC row surprises people. Armour looks like protection against a spade, but the IET's March 2025 article explains that where armoured cable is buried direct, "the cable must be earthed", which "is not possible in an unearthed system". Its summary is that "suitably impact rated insulated ducting to N750 and insulated and sheathed cable" meet BS 7671. Three of the IET articles cited here refer to earlier editions of BS 7671. The IET says A2:2022 is now obsolete for new work, its transition having ended on 15 October 2026, and that A4:2026 is current, so regulation numbers should be checked against it. The wiring and isolators guide covers DC cable and switchgear checks.

How is a buried route laid out and marked?

  • Depth. The IET says buried cables, conduits and ducts "shall be at a sufficient depth to avoid being damaged by any reasonably foreseeable disturbance of the ground", which it calls "an engineering judgment made by the designer". Where ground preparation does not meet highway standards, IET Guidance Note 1 recommends at least 500 mm. A table note the IET reproduces says depths in soft ground "should be increased by 400 mm".
  • Marking. Buried cable routes must be marked "by cable covers or a suitable marker tape".
  • Ducts. The IET's solar code recommends N750 for buried PV cable, and says additional measures should limit "access to rodents, rabbits" at duct ends. Ducts should be sealed because "ducting can fill with water".
  • The law. The Electricity Safety, Quality and Continuity Regulations require buried cables to be installed "at a sufficient depth, or otherwise protected, to avoid damage or danger".
  • Digging. The HSE's guide HSG47 is aimed at everyone "carrying out work on or near underground services" and outlines the dangers of working near them.

Ask for a drawing of the finished route so that nobody digs into it later.

Where do the isolators go?

The IET says "inverters require a means of isolation from both the AC and DC side of the installation", so the isolators follow the inverter: at the house end if the inverter is indoors, at the array if it is on or beside the frame. The same article warns that "incorrectly rated or poorly installed DC switch-disconnectors are a major contributor to PV-related fires in the UK", and that the heat inside an outdoor enclosure "should be considered". Switch sizing and labelling are in the wiring guide above.

What should a ground-mount quote show?

  • The frame make and model, and whether it is MCS 012 certified.
  • The footing type, why it suits the soil, and any ground investigation.
  • The structural and wind loading calculations.
  • The planning position, in writing.
  • The route length, and the cable type and size for each section.
  • The voltage-drop result, the duct class, the depth and the marker.
  • The inverter and isolator positions.

The ground-mounted installation page sets out the work in order, and readers can send an enquiry through the form on this site.

Sources

Common questions

Does a large ground array need the network operator's approval?

MCS says that under Engineering Recommendation G98, for installations under 16 amps per phase, the network operator must be notified no later than 28 days after commissioning. Under G99, above 16 amps per phase, prior permission to connect must be granted first. A ground frame makes a bigger array possible, so the size should be checked at the design stage.

What does N750 mean on a duct?

The IET explains that the code letter N means normal resistance to impact, and the number gives the resistance to compression. Types N450 and N750 are intended to be buried directly in the ground without additional precautions. The IET's solar code recommends N750 for buried PV cable.

Does wet or soft ground change the cable depth?

It can. The IET says that in some cases, particularly undeveloped land, a ground survey or the advice of a civil engineering groundworks specialist may be needed. A table note it reproduces says depths in soft ground should be increased by 400 mm.

Can a ground-mounted array be MCS certified?

MCS says its certification covers installations of small-scale renewables up to 50 kW for electrical technologies, and its installation standard outlines the requirements for the design and installation of solar PV systems. Ask the installer to confirm in writing that the ground array will be certified.